Cleaning and Care  
4
Installation and Adjustment of the Temperature Knob
Failure to do so may cause injury.
17T Series Installation
16
Adjust temperature limit stop! Turn on 
water supplies; LET THE WATER RUN 
AT BOTH FULL HOT AND FULL COLD 
TO ENSURE THE WATER IS RUNNING 
AS HOT/COLD AS POSSIBLE. Place 
a thermometer in a plastic tumbler, and 
hold the tumbler in the water stream. 
Place the temperature knob (1) onto the 
splines (2), then rotate the temperature 
knob until you achieve your maximum 
desired temperature from the outlet (not 
more than 120° or the lower temperature 
mandated by your local plumbing code). 
Remove the temperature knob and replace 
onto the splines (2), making sure that the 
temperature knob limit stop (3) hits against 
the volume handle limit stop (4) as shown. 
Secure the temperature knob using screw 
(5) and place cap (6) on knob. 
1
3
2
1
4
3
5
6
4
Care should be given to the cleaning 
of this product. Although its finish is 
extremely durable, it can be damaged by 
harsh abrasives or polish. To clean, simply 
wipe gently with a damp cloth and blot dry 
with a soft towel.
Warning: 
Scrubbing Bubbles
®
 Bathroom 
Cleaner and Lysol
®
 Basin Tub and Tile 
Cleaner must not be used on the clear knob 
handles and levers. Use of these cleaners 
can result in cracked or severely damaged 
handles. If overspray gets onto the handles, 
immediately wipe them dry with a soft  
cotton cloth