Chapter 4 Parameters
VFD-EL-W
4-44
02.19 User-defined Value 2
Settings Read only Default: 0
For example, assume that the frequency source is the first frequency + the second frequency command (the
first frequency source is the digital keypad and the second frequency source is AVI), the user-defined value 1
is set to 180.0 (Pr.00.13 is set to 1800; Pr.00.14 is set to 1).
When AVI=2V, the user-defined value is 36.0 [180.0/(2V/10V)], and the frequency is 12.0 Hz
[36.0/(180.0/60.0)].
When Pr.02.18=30.0, the frequency is 10.0 Hz [30.0/(60.0/180.0)].
At this time, the keypad displays 66.0 (36.0+30.0), and the output frequency is 22.0 Hz (12.0+10.0). If you read
the values by using the communication address, the values display as follows: 2102H and 2103H are 22.0 Hz;
0212H (Pr.02.18) is 30.0 Hz; 0213H (Pr.02.19) is 66.0.