Chapter 16 PLC Function ApplicationsC2000 Plus 
 
16-7 
16-3-2  I/O device explanation   
Input devices:   
Serial 
No. 
X0  X1  X2  X3  X4  X5  X6  X7  X10  X11  X12  X13  X14  X15  X16  X17 
1  FWD REV MI1 MI2 MI3 MI4 MI5 MI6 MI7 MI8             
2  MI10 MI11 MI12 MI13 MI14 MI15 
3  MI10 MI11 MI12 MI13  
1: Control I/O | 
2: Extension card: EMC-D611A (D1022=4) 
3: Extension card: EMC-D42A (D1022=5) 
Output devices:   
Serial 
No. 
Y0  Y1  Y2  Y3  Y4  Y5  Y6  Y7  Y10  Y11  Y12  Y13  Y14  Y15  Y16  Y17 
1 RY1 RY2  MO1 MO2  
2  MO10 MO11   
3   RY10 RY11 RY12 RY13 RY14 RY15  
1: Control I/O | 
2: Extension card: EMC-D42A (D1022=5) 
3: Extension card: EMC-R6AA (D1022=6) 
 
16-3-3 Installation WPLSoft 
Download and install WPLSoft editing software in Delta’s website:   
After completing installation, the WPLSoft program will be installed in the designated subfolder “C: 
\Program Files\Delta Industrial Automation\WPLSoft x.xx”. 
16-3-4 Program writing 
Step 1: Click on the WPLSoft icon to start the editing software. (See figure 16-1) 
 
 
Figure 16-1 (Left: WPLSoft icon; Right: Start WPLSoft)