Chapter 7 Optional AccessoriesC2000 Plus 
 
7-64 
7-5  Zero Phase Reactors 
Reactor Model*  Recommended Wire Size  Wiring Method  Max. Wiring Q’ty 
RF008X00A  ≤ 8 AWG  ≤ 8.37 mm
2
 Diagram A 
1C*3  
or  
4C*1 
T60006L2040W453  ≤ 8 AWG  ≤ 8.37 mm
2
 Diagram B 
RF004X00A  ≤ 1 AWG  ≤ 42.41 mm
2
 
Diagram A 
1C*3  
or  
4C*1 
T60006L2050W565  ≤ 1 AWG  ≤ 42.41mm
2
 
Diagram B 
RF002X00A  ≤ 600 MCM  ≤ 304 mm
2
 Diagram A 
1C*3  
or  
4C*1 
T60006L2160V066  ≤ 600 MCM  ≤ 304 mm
2
 
Diagram B 
RF300X00A  ≤ 350 MCM  ≤ 185 mm
2
 
Diagram A 
1C*12 
or 
4C*3 
Table 7-71 
NOTE:  
1.  Mark * means that motor cable is a 600V insulated power cable. 
2.  The table above only considers the motor cable size 
3.  For the max. wiring quantity, refer to Chapter 5 Main Circuit Terminal. 
Diagram A 
Put all wires through at least one core without winding. 
 
Figure 7-39   
Diagram B 
 
Figure 7-40