Chapter 14 Fault Codes and DescriptionsC2000 Plus 
 
ID*  Display on LCD Keypad  Fault Name  Fault Descriptions 
43 
 
PG feedback loss 
(PGF2) 
Pr.10-00 and Pr.10-
02 is not set in the PG control mode. 
When press “RUN” key, PGF2 fault occurs. 
Action and Reset 
Action condition  Software detection 
Action time  Act immediately 
Fault treatment parameter  N/A 
Reset method  Manual reset 
Reset condition  Reset immediately 
Record  Yes 
Cause  Corrective Actions 
Incorrect setting of encoder 
parameter 
Reset encoder parameters (Pr.10-00 and Pr.10-02) 
Incorrect selection of the control 
mode 
Choose the correct control mode.