Chapter 14 Fault Codes and DescriptionsC2000 Plus
14-85
ID* Display on LCD Keypad Fault Name Fault Descriptions
90
Force to stop (FStp) Keypad forces PLC to Stop
Action and Reset
Action condition
When Pr.00-32 = 1, STOP button on the keypad is valid. When giving the STOP
command during the PLC operation, FStp fault occurs.
Action time Act immediately
Fault treatment parameter N/A
Reset method Manual reset
Reset condition Reset immediately
Record Yes
Cause Corrective Actions
Pr. 00-32=1: keypad STOP button
is valid
Check if it is necessary to set Pr.00-32 = 0, so the keypad STOP button is invalid.
Press STOP button during PLC
operation
Verify the timing of STOP function.