Chapter 12 Descriptions of Parameter SettingsC2000 Plus 
 
12.1-02-9 
Settings  Functions  Descriptions 
3. MI=35 (enable single-point positioning), MO=39 (position 
reached), Pr.10-01=1024 (encoder PPR), Pr.11-65=0 and Pr.11-
66=0 
In position control mode (Pr.00-10=1), activate MI=35 (enable 
single-point positioning), the motor runs through the z-phase to 
finish single revolution coordinate system before executing 
single-point positioning function if single revolution coordinate 
system is not finished. See the diagram below: 
 
36 
Enable multi-step 
position teaching 
function 
Multi-step position teaching function can execute no matter the 
motor drive is RUN or STOP.
 
ON / OFF: the drive determines the corresponding multi-step 
positions according to MI1–MI4 ON / OFF status, and the 
motor’s current positions are written into these corresponding 
multi-step positions..