Chapter 11 Summary of Parameter SettingsMS300
247
Pr.
Explanation
Settings
Default
09-21
Block Transfer 11
0–65535
0
09-22
Block Transfer 12
0–65535
0
09-23
Block Transfer 13
0–65535
0
09-24
Block Transfer 14
0–65535
0
09-25
Block Transfer 15
0–65535
0
09-26
Block Transfer 16
0–65535
0
09-30
Communication Decoding
Method
0: Decoding method 1
1: Decoding method 2
1
09-33
PLC Command Force to 0
0–65535
0
09-35
PLC Address
1–254
2
09-36
CANopen Slave Address
0: Disable
1–127
0
09-37
CANopen Speed
0: 1 Mbps
1: 500 Kbps
2: 250 Kbps
3: 125 Kbps
4: 100 Kbps (Delta only)
5: 50 Kbps
0
09-39
CANopen Warning Record
bit 0: CANopen software disconnection 1
(CANopen guarding time-out)
bit 1: CANopen software disconnection 2
(CANopen heartbeat time-out)
bit 3: CANopen SDO time-out
bit 4: CANopen SDO buffer overflow
bit 5: CANopen hardware disconnection warning
(CANopen bus off)
bit 6: CANopen format error warning
(Error protocol for CANopen)
0
09-40
CANopen Decoding
Method
0: Use Delta-defined decoding method
1: Use CANopen standard DS402 protocol
1
09-41
CANopen Communication
Status
0: Node reset state
1: Com reset state
2: Boot up state
3: Pre-operation state
4: Operation state
5: Stop state
Read only