Chapter 12 Descriptions of Parameter SettingsMS300
297
12: Output stop
12-1-1-11
13: Cancel the setting of auto-acceleration / auto-deceleration time
15: Rotating speed command from AVI
12-1-1-12
16: Rotating speed command from ACI
12-1-1-13
18: Force to stop (Pr.07-20)
12-1-1-14
19: Digital up command
12-1-1-15
20: Digital down command
12-1-1-16
21: PID function disabled
12-1-1-17
22: Clear the counter
12-1-1-18
23: Input the counter value (MI6)
12-1-1-19
24: FWD JOG command
12-1-1-20
25: REV JOG command
12-1-1-21
26: TQC / FOC mode selection
12-1-1-22
27: ASR1 / ASR2 selection
12-1-1-23
28: Emergency stop (EF1)
12-1-1-24
29: Signal confirmation for Y-connection
12-1-1-25
30: Signal confirmation for -connection
12-1-1-26
31: High torque bias (Pr.11-30)
12-1-1-27
32: Middle torque bias (Pr.11-31)
12-1-1-28
33: Low torque bias (Pr.11-32)
12-1-1-29
38: Disable writing EEPROM function
12-1-1-30
39: Torque command direction
12-1-1-31
40: Force coasting to stop
12-1-1-32
41: HAND switch
12-1-1-33
42: AUTO switch
12-1-1-34
48: Mechanical gear ratio switch
12-1-1-35
49: Enable drive
12-1-1-36
50: Slave dEb action to execute
12-1-1-37
51: Selection for PLC mode bit 0
12-1-1-38
52: Selection for PLC mode bit 1
12-1-1-39
53: Trigger CANopen quick stop
12-1-1-40
56: Local / Remote selection
12-1-1-41
58: Enable fire mode (with RUN command)
12-1-1-42
59: Enable fire mode (without RUN command)
12-1-1-43
70: Force auxiliary frequency return to 0
12-1-1-44
71: Disable PID function, force PID output return to 0
12-1-1-45
72: Disable PID function, retain the output value before disabled
12-1-1-46
73: Force PID integral gain return to 0, disable integral
12-1-1-47
74: Reverse PID feedback
12-1-1-48
81: Simple positioning zero point position signal input
12-1-1-49
82: OOB loading balance detection
12-1-1-50
83: Multi-motor (IM) selection bit 0
12-1-1-51