Chapter 9 Specification  C2000  Plus 
 
UL Open Type: 
The rated output current derating (%) in normal duty / light duty / heavy duty when carrier frequency is the   
default value: 
  100% Load 
Fc (kHz) 
30°C  50°C  60°C 
Default Value  100  100  80 
Table 9-12    
UL Open Type_Side by Side or UL Type 1: 
The rated output current derating (%) in normal duty / light duty when carrier frequency is the default value: 
  100% Load 
Fc (kHz) 
30°C  40°C  60°C 
Default Value  100  100  60 
Table 9-13    
575V/690V models
 
50
60
70
80
90
100
30 35 40 45 50 55 60
Drive's Rated Output Current (%)
Ambient Temperature (
°C)
Derating for Ambient Temperautre
ND / LD / HD [Fc = Default] (UL Open Type)
ND / LD [Fc = Default] (UL Open Type_Side by Side or UL Type 1)
 
Figure 9-3   
UL Open Type: 
The rated output current derating (%) in normal duty / light duty / heavy duty when carrier frequency is the 
default value: 
  100% Load 
Fc (kHz) 
30°C  50°C  60°C 
Default Value  100  100  75 
Table 9-14    
UL Open Type_Side by Side or UL Type 1: 
The rated output current derating (%) in normal duty / light duty when carrier frequency is the default value: 
  100% Load 
Fc (kHz) 
30°C  40°C  60°C 
Default Value  100  100  50 
Table 9-15