Chapter 12 Descriptions of Parameter SettingsC2000 Plus 
 
12.1-02-8 
Settings  Functions  Descriptions 
35 
Enable single-point 
positioning 
ON: the AC motor drive executes the single-point positioning   
according to Pr.11-65 (single-point positioning position high 
byte) and Pr.11-66 (single-point positioning position low byte). 
This function is valid only for IMFOCPG and PMFOCPG control 
modes. 
1. MI=35 (enable single-point positioning), MO=39 (position 
reached), Pr.10-01=1024 (encoder PPR), Pr.11-65=0 and Pr.11-
66=0 
In speed control mode (Pr.00-10=0), activate MI=35 (enable 
single-point positioning), the motor is positioned according to 
Pr.11-65 and Pr.11-66 settings. See the diagram below:   
   
2. MI=35 (enable single-point positioning), MO=39 (position 
reached), Pr.10-01=1024 (encoder PPR), Pr.11-65=0 and Pr.11-
66=3072 
In position control mode (Pr.00-10=1), activate MI=35 (enable 
single-point positioning), the motor runs from the current single 
revolution position to Pr.11-65 and Pr.11-66 setting positions and 
the moving position does not exceed one revolution if single 
revolution coordinate system is finished. See the diagram below: