Chapter 13 Warning CodesC2000  Plus 
 
ID No.  Display on LCD Keypad  Warning Name  Description 
129 
 
SW POS Limit (SPL) 
When under FOCPG mode, the feedback position of 
the motor is higher than or equal to the software 
positive limit set by the parameters. 
Action and Reset 
Action condition  Pr.11-56, Pr.11-57 
Action time  Immediately acts 
Warning Setting Parameter  N/A 
Reset method  Move the motor away from the limit position, the warning automatically clears. 
Reset condition  Immediately resets 
Record  N/A 
Cause  Corrective Actions 
Error occurs on software limit 
switch 
Verify if the setting of software limit switch at Pr.11-56 and Pr.11-57 is correct.   
Overshoot 
1.  Verify if the acceleration/ deceleration time of the motor drive is correct. 
2.  Verify if the frequency command of the motor drive is correct.