Chapter 14 Fault Codes and DescriptionsC2000 Plus
14-82
ID* Display on LCD Keypad Fault Name Fault Descriptions
86
PG UVW line off
(UvoF)
UVW line off for protection when using PG02U
Action and Reset
Action condition Hardware detection
Action time Act immediately
Fault treatment parameter N/A
Reset method Manual reset
Reset condition Reset immediately
Record Yes
Cause Corrective Actions
The UVW signal is cut off
Check if the signal cable between encoder and PG card is correct or cut off.