Chapter 12 Descriptions of Parameter SettingsMS300
316
02-50
Display the Status of Multi-Function Input Terminal
Default: Read only
Settings
Monitor the status of the Multi-function Input Terminal
Example:
When Pr.02-50 displays 0034h (hex) (that is, the value is 52 (decimal) and 0110100 (binary)), it
means that MI3, MI5 and MI6 are ON.
02-51
Display the Status of Multi-Function Output Terminal
Default: Read only
Settings
Monitor the status of the Multi-function Output Terminal
Example:
When Pr.02-51 displays 0009h (hex) (that is, the value is 9 (decimal) and 01001 (binary)), it
means that Relay and MO1 are ON.