Chapter 13 Warning CodesMS300
507
ID No.
Display on LCD Keypad
Warning Name
Description
46
CANopen format error
(CPtn)
CANopen protocol format error
Action and Reset
Action Condition
The slave detects that communication data from the upper unit cannot be
recognized, and then CPtn warning occurs.
Action Time
Immediately act when the fault is detected
Warning Setting Parameter
N/A
Reset Method
The upper unit sends a reset packet to clear the warning
Reset Condition
N/A
Record
N/A
Cause
Corrective Actions
The upper unit sends incorrect
communication packet
Make sure the master sends the packet based on CANopen DS301 standard
command format.