Chapter 13 Warning CodesMS300
541
ID No.
Display on LCD Keypad
Warning Name
Description
93
Copy PLC: version
error (CPLv)
Copy PLC version error.
When a non-MS300 built-in PLC is copied to the
MS300 drive, the CPLv warning occurs.
Action and Reset
Action Condition
Software detection
Action Time
Immediately act
Warning Setting Parameter
N/A
Reset Method
Manual reset
Reset Condition
Directly reset
Record
N/A
Cause
Corrective Actions
A non-MS300 PLC program is
copied to MS300
Check if the copied PLC program is for MS300.
Use the correct MS300 PLC program.