Chapter 15 CANopen Overview C2000 Plus 
 
 
15-14 
Home mode 
1.  Set 6098 = 1–35 to choose a home method. 
2.  Set the left and right limits correspond to the position of MI terminal. 
3.  Switch to Home mode: set Index 6060 = 6. 
4.  Switch to Operation Enable mode: set 6040 = 0xE, and then set 6040 = 0xF. 
5.  To trigger an ACK signal: set 6040 = 0x0F, and then set 6040 = 0x1F (Pulse On, and the motor 
drive will be back to home.) 
NOTE: Read bit12 of 6041 to find if the home mode is completed. (0: Not reached, 1: reached)