Chapter 16 PLC Function ApplicationsC2000 Plus
16-92
API
SIN
Binary floating point number SIN operation
130
D P
Bit device Word device
16-bit command
32-bit command (9 STEP)
DSIN Continuous
execution type
DSINP Pulse
execution type
Flag signal: none
X Y M K H KnX KnY KnM T C D
S * * *
D *
Notes on operand usage:
Please refer to the function specifications table for each device in series
for the scope of device usage
S: the designated source value. D: the SIN value result.
S is the designated source in radians.
The value in radians (RAD) is equal to (angle ×π/180).
The SIN obtained from the source value designated by S is stored in D.
The following figure displays the relationship between the arc and SIN results:
When X0=On, the SIN value of the designated binary floating point number (D1, D0)
in radians (RAD) will be stored in (D11, D10), with the content consisting of a binary
floating point number.
X0
DSIN D0 D10