Chapter 12 Descriptions of Parameter SettingsC2000 Plus
12.1-02-7
Settings Functions Descriptions
26
TQC / FOC mode
selection
ON: TQC mode.
OFF: FOC mode.
27
ASR1 / ASR2 selection
ON: the speed is adjusted by the ASR 2 setting.
OFF: the speed is adjusted by the ASR 1 setting.
Refer to Pr.11-02 for details.
28 Emergency stop (EF1)
ON: the output of the drive stops immediately, displays “EF1” on
the keypad, and the motor is in free run status. The drive keeps
running until the fault is cleared after you press RESET on the
keypad (EF: External Fault).
29
Signal confirmation for Y-
connection
When the control mode is V/F, ON: the drive operates by the first
V/F.
30
Signal confirmation for -
connection
When the control mode is V/F, ON: the drive operates by the
second V/F.
31
High torque bias
(Pr.11-31)
Refer to Pr.11-30–Pr.11-32 for details.
32
Middle torque bias
(Pr.11-32)
33
Low torque bias
(Pr.11-33)