EasyManuals Logo

Delta VFD4A2ME43ANNAA User Manual

Delta VFD4A2ME43ANNAA
403 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #148 background imageLoading...
Page #148 background image
Chapter 11 Summary of Parameter SettingsME300
11-5
Pr. Explanation Settings Default
01Axh: inWG
01Bxh: ftWG
01Cxh: Psi
01Dxh: Atm
01Exh: L/s
01Fxh: L/m
020xh: L/h
021xh: m3/s
022xh: m3/h
023xh: GPM
024xh: CFM
00-26
Maximum user-defined
value
0: Disable
0–65535 (when Pr.00-25 set to no decimal place)
0.0–6553.5 (when Pr.00-25 set to 1 decimal place)
0.00–655.35 (when Pr.00-25 set to 2 decimal places)
0.000–65.535 (when Pr.00-25 set to 3 decimal places)
0
00-27 User-defined value Read only Read only
00-29 LOCAL / REMOTE mode
0: Standard HOA function
1: When switching between local and remote, the drive
stops.
2: When switching between local and remote, the drive
runs with REMOTE settings for frequency and
operation status.
3: When switching between local and remote, the drive
runs with LOCAL settings for frequency and operation
status.
4: When switching between local and remote, the drive
runs with LOCAL settings when switched to Local and
runs with REMOTE settings when switched to Remote
for frequency and operation status.
0
00-30
Master frequency
command (HAND) source
0: Digital keypad
1: RS-485 communication
2: External analog input (refer to Pr.03-00)
3: External UP/DOWN terminal
7: Digital keypad dial
0
00-31
Operation command
(HAND) source
0: Digital keypad
1: External terminals
2: RS-485 communication
0
00-32
Digital keypad STOP
function
0: Disable STOP key
1: Enable STOP key
0

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Delta VFD4A2ME43ANNAA and is the answer not in the manual?

Delta VFD4A2ME43ANNAA Specifications

General IconGeneral
BrandDelta
ModelVFD4A2ME43ANNAA
CategoryDC Drives
LanguageEnglish

Related product manuals