Chapter 12 Description of Parameter SettingsME300
12.1-06-17
Status 3: The drive is in STOP; Pr.06-48 ≠ 0; Pr.07-02 ≠ 0
When the drive starts, it executes Pr.06-48 first, and then executes Pr.07-02 (DC brake). The DC
brake current level in this state includes two parts: one is 20 times the Pr.06-47 setting value in
Pr.06-48 setting time; the other is the Pr.07-01 setting value in Pr.07-02 setting time. In this
period, if an OPHL happens within the time for Pr.06-48, the drive executes the Pr.06-45 setting
after the drive starts counting for half the time of Pr.06-48.