17
AVR-4310CI/AVR-4310/AVC-4310
1.3. Error display
See the following table for each "Error information" display and its contents (status). Display order is ①②③④⑤⑥ .
2. Displaying the protection history mode
2.1. Operation specifications
ERROR MODE(displaying the protection history)
When started up, the error information is displayed.
Starting up:
With the "MENU" and "STATUS" buttons pressed, press the "ON/OFF" button to turn the power on. The error (protection 
history display) mode is set.
Then, press the "STATUS" button to turn on the FL display.
2.2. About the display on the FL display
When the "STATUS" button is pressed after setting the error (protection history display) mode, a history like the one shown 
below is displayed, depending on the conditions.
(1) Normally (when there has been no protection incident)
(2) For ASO/DC (when the last protection incident was ASO or DC protection)
(3) For THERMAL (when the last protection incident was THERMAL protection)
When the "STATUS" button is pressed again after the above protection history is displayed, the normal display reappears.
Condition State  Display
①
Sub-µcom 
     NG
No response from Sub-µcom
"□SUB□ □ERROR□01□□"
② DIR NG
No response from DIR
"□DIR□ □ERROR□01□□"
③ DSP1 NG
When DSP boot, executing DSP reset makes no change to DSP1 FLAGO port "H".
"□DSP1 □ ERROR□01□ □"
No change to DSP1 FLAGO port "H" before issuing DSP command.
"□DSP1 □ ERROR□02□ □"
When DSP data read, executing WRITE="L" makes no change to ACK="H".
"□DSP1 □ ERROR□03□ □"
When DSP data read, executing REQ="L" makes no change to ACK="L".
"□DSP1 □ ERROR□04□ □"
When DSP data write, executing WRITE="H" makes no change to ACK="H".
"□DSP1 □ ERROR□05□ □"
When DSP data write, executing REQ="L" makes no change to ACK="L".
"□DSP1 □ ERROR□06□ □"
When DSP special code boot, executing DSP reset makes no change to DSP1 
FLAGO port "H".
"□DSP1 □ ERROR□11□ □"
No change to DSP1 FLAGO port "H" before issuing DSP special read command.
"□DSP1 □ ERROR□12□ □"
No change to DSP1 FLAGO port "H" before DSP version read.
"□DSP1 □ ERROR□13□ □"
④ DSP2 NG
When DSP boot, executing DSP reset makes no change to DSP2 FLAGO port "H".
"□DSP2 □ ERROR□01□ □"
No change to DSP2 FLAGO port "H" before issuing DSP command.
"□DSP2 □ ERROR□02□□" 
When DSP data read, executing WRITE="L" makes no change to ACK="H".
"□DSP2 □ ERROR□03□ □"
When DSP data read, executing REQ="L" makes no change to ACK="L".
"□DSP2 □ ERROR□04□ □"
When DSP data write, executing WRITE="H" makes no change to ACK="H".
"□DSP2 □ ERROR□05□ □"
When DSP data write, executing REQ="L" makes no change to ACK="L".
"□DSP2 □ ERROR□06□ □"
When DSP special code boot, executing DSP reset makes no change to DSP2 
FLAGO port "H".
"□DSP2 □ ERROR□11□ □"
No change to DSP2 FLAGO port "H" before issuing DSP special read command.
"□DSP2 □ ERROR□12□ □"
No change to DSP2 FLAGO port "H" before DSP version read.
"□DSP2 □ ERROR□13□ □"
⑤ EEPROM NG
Error appeared in EEPROM checksum.(*** is a block address number.)
"□E2PROM□ERR***□ □"
⑥
Both SUB/DSP
       /EEPROM OK
(No error display, version display only)
P
ROTEC T H I S TORY
:
NO PROTECT
P
ROTEC T H I S TORY
:
ASO / DC
P
ROTEC T H I S TORY
:
THERMAL