EasyManua.ls Logo

Denon S-52 - Rewriting the Default Value of the Laser Current

Denon S-52
102 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
27
S-52/S-52DAB/S-32
4. Rewriting the default value of the laser
current
To rewrite the default value of the laser current, press the
button for at least 5 seconds while the CD laser current
is displayed, then press the or button to select
T23. (For details, see "Iop checked Method" on page 26.)
If the button is pressed while T23 is displayed, the cur-
rent value is displayed at "mmmm" and stored in the EE-
PROM.
5. Resetting the accumulated laser on time
To clear the accumulated laser on time, press the button
while the accumulated laser on time is displayed (TB1: For
details, see "Test Mode" on page 32.) until " " appears at
the fourth position, the accumulated laser on time of CD is
cleared.
When TB1 is selected, "nnnnnnn" is displayed as 0 so you
can check.
( : Off, nnnnnnn: Hour [h])
Display(Thedisplaypartof13digits)
12345678910111213
3 mmmm
Display(Thedisplaypartof13digits)
12345678910111213
BYnnnnnnn
4. レーザー電流初期値の書き換え方法
レーザー電流の初期値を書き換えるには、CD レーザー電流
が表示されている時に ボタンを 5 秒以上押し次に
ボタンまたは ボタンを押して T23 を選択しま
す。(詳細は 26 ページ、Iop 値の確認方法参照)
T23 表示時に ボタンを押と、mmmm 部に現在値を表示
し、EEPROM に保存します。
5. レーザー ON 累積時間のリセット方法
レーザーON 累積時間をクリアするには、レーザーON
積時間表示 (TB1) の時(詳細は 32 ページ、テストモード参
照)に ボタンを 4 桁目に ' ' が表示されるまで押し、
CD レーザー ON 累積時間をクリアします。
ボタンまたは ボタンで TB1 を選択すると
nnnnnnn 部が 0 表示となり確認できます。
( −:消灯、nnnnnnn:時間 [h])
表示 (13 桁の表示部 )
12345678910111213
T2 3 mmmm―――――
表示 (13 桁の表示部 )
12345678910111213
BYnnnnnnn