11
6.4 GENERAL CONDITION
Regularly inspect the condition of the unit for signs of damage, wear or malfunction.
• Ensure that the unit is securely attached to the oor & the seals are functioning
correctly.
• Check that the unit does not touch the sides of the oor cutouts - this may cause
noticeable vibration through the oor.
• Visually inspect the supply cord for signs of wear or damage.
• Check that the exible duct and remote cable are secure free from damage.
If any problems are found, immediately disconnect the unit & contact your nearest
service agent for assistance.
7. TECHNICAL DATA
Unit: UB1 Air-conditioner Part No. TA448006-6220
Application: Caravan, camper and pop-top recreational vehicles
Nominal Cooling Capacity: 2.6 kW (T1)
Nominal Heating Capacity: 2.0 kW (H)
Dimensions: 898mm (length) x 458mm (width) x 265mm (height)
Weight: 45kg
Power Supply: 230-240V, 50 Hz
Rated Current: 8 A
Airow Volume: 360 m
3
/h
Refrigerant: R407c
Refrigerant Amount: 750 g
Maximum operating incline: 8°
Operating Temperature Range: Cooling (16-45°C) Heating (0-25°C)