42
8-6 Checking/every 500 hours
(1) Replacement of air cleaner element
The element should be replaced referring to "Cleaning of air cleaner element"
(See p.40) every 500 hours or 2 years.
In situations where the generator has not been operated for 500 hours or more, as a
general rule, the air cleaner will need to be replaced after it has been cleaned 6 times.
(2) Cleaning of radiator
When the fin or tube is blinded, it should be cleaned with steam or running water.
Do not use a high pressure washer to prevent damage to the fin and tube.
8-7 Checking/every 1000 hours
(1) Cleaning inside of fuel tank
Drain the fuel in the fuel tank completely, and wash out
deposits and water collected inside the tank.
(2) Adjust fuel injection nozzle
8-8 Checking/every 2000 hours
(1) Measure the engine compression pressure
(2) Check the valve clearance
(3) Replacement of radiator water (if LLC is used)
(4) Check on nylon and rubber hose
Check on the nylon and rubber hose whether they are hardened or deteriorate.
Contact distributor or our office to replace the nylon hose and rubber hose, if
necessary.
(5) Checking for terminal and connection of the circuit.
Check for main and sub circuit whether there are no abnormality such as loosening,
corrosion and burning, etc.
8-9 Other Checks and Maintenance
(1) Check on lining
Check on the lining whether it deteriorates greatly, or it is stained by clinging of oil
or the like, or it is removed. Contact distributor or our office to replace the lining, if
necessary.