Installation and Operation Manual
• 100% Outdoor Air
Systems & High
Outdoor Air Systems
Aura™ (QS), dedicated
outdoor air system,
offers a high quality
dehumidifier with
various options to
cover multiple
applications
TotalAire™ (QS),
dedicated outdoor air
systems, offers an
optional energy
recovery wheel that
recovers both sensible
and latent heat.
• VerticalAire™ (QV),
dedicated outdoor air
system, is a high-
quality cost-effective
dehumidifier that’s
designed for tight
spaces
Indoor Air Quality
Aura™ (QS)
TotalAire™ (QS)
VerticalAire™ (QV)
TotalAire™ (QS)
Dehumidifier
VerticalAire™ (QV)
Dehumidifiers
Aura™ (QS)
Dehumidifier

Table of Contents

Questions and Answers

  • J
    Joe FloresAug 9, 2025
    What to do if my Desert Aire TotalAire QS Dehumidifier compressor does not run?
    • J
      Jon LaneAug 9, 2025
      If your Desert Aire Dehumidifier's compressor isn't running, start by checking for a tripped circuit breaker or blown fuses to restore main power. Also, verify that the blower and compressor overloads haven't tripped; correct the cause and reset them if needed. Inspect the wiring for any loose or faulty connections on both the system and the dehumidifier. If the compressor starts but doesn't pump, or if the motor windings are shorted, the compressor may need replacement. Finally, if none of these are the cause, wait 3 minutes to account for any compressor delay time.
  • W
    Wendy MccallAug 17, 2025
    How to fix a Desert Aire Dehumidifier when the blower does not run?
    • D
      dbarkerAug 17, 2025
      If your Desert Aire Dehumidifier blower isn't running, ensure the “Occupied” switch is closed. Check for a loss of main power by looking for tripped circuit breakers or blown fuses. Make sure the damper isn't stuck or frozen, preventing the actuator end switch from closing; free the damper or replace the actuator if defective. Also, check if the blower overload has tripped; if so, correct the cause and reset it. Finally, inspect the control wiring for any loose or incorrect connections on the system and controller.
  • S
    Stacie WhiteSep 1, 2025
    What to do if my Desert Aire TotalAire QS has low pressure alarms or evaporator coil icing?
    • K
      kellyfranciscoSep 1, 2025
      If your Desert Aire Dehumidifier is experiencing low-pressure alarms (below 97 PSIG) or evaporator coil icing, there are several potential causes. First, check the hot-gas bypass valve to ensure it's properly set to maintain 30°F suction (97 PSIG); replace it if defective. Ensure sufficient evaporator airflow by verifying the coil is clean and the belts are tight. Re-evaluate the system charge if there is a lack of refrigerant. Check the refrigerant filter-drier for restrictions and replace it if necessary. Evaluate the expansion valve performance and replace it if defective. Lastly, inspect the refrigeration piping for restrictions, such as kinks in the tubing or debris in the distributor.
  • N
    nicholas98Nov 23, 2025
    Why does my Desert Aire TotalAire QS show high pressure alarms?
    • M
      michaelrodriguezNov 23, 2025
      If your Desert Aire Dehumidifier is showing high pressure alarms or readings above the high-pressure trip set point, several factors could be responsible. For units with air-cooled condensers, ensure the coil is clean and there are no airflow restrictions. Check that the remote condenser blower is running and has power at the motor leads. For units with tower condensers, verify adequate water flow by installing a flow meter or circuit setter to ensure the correct flow rate. If the incoming water temperature is above 90°F, consult the factory for required flow rates. Purge the lines to eliminate excessive air in the condenser water lines, or install an air eliminator in the system piping. For 3-phase systems, reduce blower speed and reset the overload if it has tripped. Replace the contacto...

Summary

Desert Aire Dehumidification Equipment Standard Limited Warranty

Gas Heater Safety and Operation

Safety Warnings Before Operation

Crucial safety warnings for operating gas-heated appliances to prevent fire or explosion.

2 Installation

2.7. High Voltage Wiring and Connections

Instructions for safe and compliant high voltage wiring, including connections and wire sizing.

3. Start-Up Procedures

3.1. Preliminary Inspection Checklist

Essential checks before unit start-up, including shipping blocks, leveling, and electrical connections.

3.2. Optional Gas Heater Start-Up

Steps for safely starting up the optional gas heater, including wiring and gas leak tests.

3.3. Airflow Balancing

Procedures for ensuring proper airflow by adjusting blower speed and balancing dampers.

3.3. Airflow Balancing

3.3.1. Blower Adjustment Procedures

Methods for adjusting blower speed for EC blowers, units without VFDs, and units with VFDs.

3.3.2. Airflow Balancing for DOAS Units

Balancing airflow for Dedicated Outside Air Systems (DOAS) units.

3.4. Refrigeration Testing

4. Troubleshooting Common Issues

4.1. Blower Not Running

Diagnosing and resolving issues when the unit's blower fails to operate.

4.2. Compressor Not Running

Troubleshooting steps for when the compressor(s) do not start or operate correctly.

4.3. High Pressure Alarms

Identifying causes and remedies for high pressure alarms in the refrigeration system.

4.4. Low Pressure Alarms; Coil Icing

Troubleshooting low pressure alarms and evaporator coil icing issues.

5.1. Compressor Failure and Replacement

Compressor Replacement Procedures

Detailed procedures for replacing a compressor, including oil testing and system cleaning.

5.3. Recommended Controller Settings

5.4. IAQ Sequence of Operation

5.5. Component Replacement and Service

5.8. System Start-Up Report and Forms

Compressor Replacement Form

Compressor Condition and Failure Determination

Sections for documenting compressor condition, failure causes, and corrective actions.

Replacement Checklist and Data Collection

Checklist and data fields for compressor replacement, including air flow and refrigerant readings.

Desert Aire TotalAire QS Specifications

General IconGeneral
BrandDesert Aire
ModelTotalAire QS
CategoryDehumidifier
LanguageEnglish