Atomising air pressure too low.
Increase air pressure.
Intermittent or 'fluttering'
spray fan.
Loose fluid tip.
Tighten.
Thin to correct consistency.
Split spray pattern
Increase fluid flow by changing fluid
tip size, opening needle control knob
or increase fluid pressure on
pressure feed container.
Too much air for fluid quanitity used.
Fluid tip not seated correctly in gun
head.
Remove fluid tip, clean components,
check cone seating on tip and gun
for damage or contamination.
Material too thick.
Clean or replace.
Turn out counter clockwise to
achieve correct pattern.
Not enough material flow.
Too high horn pressure.
Reduce air pressure by rotating
pattern control valve clockwise.
Partially obstructed fluid passage or
hose.
Too much material.
Reduce fluid flow by turning fluid
needle adjusting screw clockwise.
Reduce fluid pressure.
Heavy centre pattern.
Pattern adjustment valve set too low.
Reduce input air pressure.