To Previous Page IconTo Previous Page
Loading...
7 - Eng
D24156
IMPORTANT: Always connect the quick connect body to the air hose. Never
connect the quick connect body to the tool.
NOTE: Excessive oil will damage o-rings and seal of tool. If in-line oiler is
used, manual lubrication through the air inlet is not required on a daily
basis.
The air compressor must be able to maintain a minimum of 65 PSI when the tool
is being used. An inadequate air supply can cause a loss of power or
inconsistent operation.
Do not use any type of flammable gases or oxygen as a power
source for the tool. Use filtered, lubricated, regulated com-
pressed air only. Use of compressed gas instead of compressed air may
cause the tool to explode and cause death or serious personal injury.
Do not use a check valve or any other fittings which will allow
air to remain in the tool. Serious personal injury or property
damage could occur.
Use a Pressure Regulator on your compressor with an
operating pressure of 0-125 PSI. A Pressure Regulator is
required to control the operating pressure of your tool. Refer to the label on
your nailer/stapler for the maximum P.S.I.
Never carry the tool by the hose or pull the hose to move the
tool or a compressor. Keep hoses away from heat, oil,
and sharp edges. Replace any damaged, weak or worn hoses.
BRAD NAILER/
STAPLER
QUICK
CONNECT
BODY
QUICK
CONNECT
PLUG
OILER
FILTER
RECOMMENDED HOOK-UP
AIR
COMPRESSOR
AIR
HOSE
(3/8" I.D.)
QUICK
CONNECT
BODY
QUICK
CONNECT PLUG
(Supplied with Tool)
The following illustration shows the proper hook-up which will help prolong the
life of the Tool.
REGULATOR