16
English
CODE POSSIBLE CAUSE POSSIBLE SOLUTION
4 Defective air tank Air tank must be replaced. Do not repair the leak.
WARNING: Risk of bursting. Do not drill into, weld or
otherwise modify air tank or it will weaken. The air tank can
ruptureorexplode.
5 Leaking seals Contact a D
e
WALT factory service center or a D
e
WALT
authorized service center.
6 Defective safety valve Operate safety valve manually by pulling on ring. If valve
still leaks, it must be replaced.
7
Regulatorisnotadjustedcorrectlyforaccessorybeing
used
It is normal for some pressure drop to occur when an acces-
soryisused,adjusttheregulatorasinstructedinRegulator
under Features if pressure drop is excessive.
NOTE:Adjusttheregulatedpressureunderflowconditions
while accessory is being used.
8 Prolonged excessive use of air Decrease amount of air usage.
9 Compressor is not large enough for accessory Check the accessory air requirement. If it is higher than
the CFM or pressure supplied by your air compressor, a
larger compressor is needed to operate accessory.
10 Hole in air hose Replace air hose.
11 Check valve restricted Contact a D
e
WALT factory service center or a D
e
WALT
authorized service center.
12 Air leaks Tighten fittings.
13 Regulator is damaged Replace.
14 Motor overload protection switch has tripped See Motor Overload under Features.