EasyManua.ls Logo

DeWalt D2002M

DeWalt D2002M
56 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
17
English
CODE POSSIBLE CAUSE POSSIBLE SOLUTION
15 Extension cord is wrong length or gauge Check for proper gauge wire and cord length. See
Extension Cords under Installation.
16
Loose electrical connections Contact a D
e
WALT factory service center or a D
e
WALT
authorized service center.
17
Possible defective motor. Contact a D
e
WALT factory service center or a D
e
WALT
authorized service center.
18
Fuse blown, circuit breaker tripped 1. Check fuse box for blown fuse and replace as necessary.
Reset circuit breaker. Do not use a fuse or circuit
breaker with higher rating than that specified for your
particular branch circuit.
2. Check for proper fuse. Use only a time delay fuse.
3. Check for low voltage conditions and/or proper extension
cord.
4. Disconnect the other electrical appliances from circuit or
operate the compressor on its own branch circuit.
19
Tank pressure exceeds pressure switch cut-in pressure Motor will start automatically when tank pressure drops
below cut-in pressure of pressure switch.