CODE POSSIBLE CAUSE POSSIBLE SOLUTION
I
i5 Tank pressure exceeds pressure switch cut-in Motor wil! start automatically when tank pressure drops below CUt-
pressure in pressure of pressure switch.
16 Extension cord is wrong length or gauge Check for proper gauge wire and cord length refer to the Extension
Cords under Installation.
17 L0ose electrical Connecti0nS check wiring Connection inside pressure Switch and terrnina! box
• area.
18 Possible defective motor Contact a DEWALT factory service center or a DEWALT authorized
service center.
Paint spiay on inteinal motor parts Contact a DEWALT factoiy seWice Center or a DEWALT authorized
' service center: Do not operate the compressor in the paint spray
! area. See flammable vapor warning.
20 Fuse blown, circuit breaker tripped 1. Check fuse box for blown fuse and replace as necessary. Reset
circuit breaker. Do not use a fuse or circuit breaker with higher
rating than that specified for our particular branch circuit.
2. Check for proper fuse. You should use a time delay fuse.
3. Check for low voltage conditions and/or proper extension cord.
4. Disconnect the other electrical appliances from circuit or operate
the compressor on its own branch circuit.
2i worn Belt Contact a DEWALT factory serVice center or a DEWALT aUth0rized
• service center.
22 Restricted air intake filter Clean or replace air intake filter. Do not operate the air compressor
with the filter removed. Refer to the Air Filter paragraph in the
Maintenance section.
2O