Minimum Gauge for Cord Sets
Ampere
Rating
Volts Total Length of Cord in Feet (meters)
120V 25 (7.6) 50 (15.2) 100 (30.5) 150 (45.7)
240V 50 (15.2) 100 (30.5) 200 (61.0) 300 (91.4)
More
Than
Not
More
Than
AWG
0 6 18 16 16 14
610 18 16 14 12
10 12 16 16 14 12
12 16 14 12 Not Recommended
Do not place any object on top of charger or place the
charger on a soft surface that might block the ventilation
slots and result in excessive internal heat. Place the charger
in a position away from any heat source. The charger is ventilated
through slots in the top and the bottom of the housing.
Do not mount charger on wall or permanently affix charger
to any surface. The charger is intended to use on a flat, stable
surface (i.e., table top, bench top).
Do not operate charger with damaged cord or plug.
Do not operate charger if it has received a sharp blow, been
dropped, or otherwise damaged in any way. Take it to an
authorized service center.
Do not disassemble charger; take it to an authorized service
center when service or repair is required. Incorrect reassembly
may result in a risk of electric shock, electrocution or fire.
Disconnect the charger from the outlet before attempting
any cleaning. This will reduce the risk of electric shock.
Removing the battery pack will not reduce this risk.
NEVER attempt to connect two chargers together.
The charger is designed to operate on standard 120 volt
household electrical power. Do not attempt to use it on any
other voltage. This does not apply to the vehicular charger.
Chargers
Your tool uses a DEWALT charger. Be sure to read all safety
instructions before using your charger. Consult the chart at the end of
this manual for compatibility of chargers and battery packs.
Charging Procedure (Fig. 1)
1. Plug the charger into an appropriate
J
FIG. 1
outlet before inserting battery pack.
2. Insert the battery pack (J) into the
charger, as shown in Figure 1, making
sure the pack is fully seated in charger.
The charger is equipped with a three-
light fuel gauge that will blink according
to the state of charge of the battery
pack.
3. The completion of charge is indicated
by the three red lights remaining ON
continuously. The pack is fully charged
and may be used at this time or left on
the charger.
0% - 33% 1
st
light blinks
33% - 66% 1
st
light on, 2
nd
light blinks
66% - 99% 1
st
, 2
nd
lights on, 3
rd
light blinks
100% 1
st
, 2
nd
, 3
rd
lights on