SYMPTOM CAUSE FIX
Tool operates but does not
drive fasteners fully
Depth adjust set too shallow Rotate depth adjust to a deeper setting.
Tool not firmly applied to workpiece Apply adequate force to tool securing it tightly to workpiece. Refer to
instruction manual.
Material and fastener length If the unit continues to stall (forcing the need to rotate the Stall release
lever) choose the appropriate material and fastener length that is not too
rigorous of an application.
Damaged or worn driver blade tip Replace driver/return assembly. See authorised DEWALT repair agent.
Damaged actuation mechanism See authorised DEWALT repair agent.
Tool is not yet run‑in New tools can take 500–1000 nails for parts to mesh and wear in
together. Drive shorter nails during this period if experiencing difficulty
driving nails flush.
Use of incorrect speed If trying to drive longer ring shank nails in soft woods, or driving ring
shank nails into harder materials in speed 1 ‑ adjust speed setting to
position 2.
Tool operates, but no fastener
is driven
No nails in magazine Load nails in magazine.
Wrong size or angle nails Use only the recommended nails. Refer to Technical Data.
Debris in nosepiece Clean nose area and watch closely for small pieces of broken nails stuck
in the track.
Debris in magazine Clean magazine.
Worn magazine Replace magazine. See authorised DEWALT repair agent.
Damaged or worn driver blade Replace driver blade. See authorised DEWALT repair agent.
Damaged pusher spring Replace spring; see authorised DEWALT repair agent.
Jammed nail Wrong size or angle nails Use only the recommended nails. Refer to Technical Data.
Damaged or worn driver blade Replace driver blade. See authorised DEWALT repair agent.
Material and fastener length If the unit continues to stall (forcing the need to rotate the Stall release
lever) choose the appropriate material and fastener length that is not too
rigorous an application.
Debris in nosepiece Clean nose area and watch closely for small pieces of broken nails stuck
in the track.
Worn magazine Replace magazine. See authorised DEWALT repair agent.
Damaged pusher spring Replace spring. See authorised DEWALT repair agent.