Generator DXGNR 5700
DXGNR 7000
If you have questions or comments, contact us.
1-888-431-6871 • dewalt.com
INSTRUCTION MANUAL
To reduce the risk of injury, read and follow these instructions before operating
product.
WARNING

Table of Contents

Questions and Answers

  • S
    silvaamyAug 18, 2025
    What to do if DeWalt DXGNR 5700 engine will not start?
    • S
      Sarah BatesAug 18, 2025
      If your DeWalt Portable Generator won't start, there are several things to check: * Ensure the fuel shut-off is turned ON. * Clean or replace the air filter if it's dirty. * Make sure you have fuel in the tank, and if the fuel is stale, drain the tank and refill with fresh fuel. * Check that the spark plug wire is connected to the spark plug, and replace the spark plug if it is bad. * Drain the fuel tank and fill with fresh fuel if there is water in the fuel. * Set the choke to the no choke position if you are overchoking. * Fill the crankcase to the correct level if the oil level is low. * Replace the fuel filter if it is dirty.
  • A
    ahernandezAug 20, 2025
    Why DeWalt DXGNR 5700 engine is running, but AC output is not available?
    • G
      gallowaydonaldAug 20, 2025
      If your DeWalt Portable Generator's engine is running but there's no AC output, here's what you can check: * Reset the circuit breaker if it's open. * Check and repair any poor connections or defective cord sets. * Try connecting another device that you know is in good condition. * If equipped, correct any ground fault and press the reset button on the GFCI receptacle.
  • K
    kimberly44Aug 23, 2025
    What to do if DeWalt DXGNR 5700 engine shuts down during operation?
    • D
      donald85Aug 23, 2025
      If your DeWalt Portable Generator engine shuts down during operation, check the following: * Ensure the fuel tank is filled. * Check that the oil level in the crankcase is at the correct level.
  • P
    pachecosusanAug 25, 2025
    Why DeWalt DXGNR 5700 Portable Generator engine lacks power?
    • M
      Martin BraunAug 26, 2025
      If your DeWalt Portable Generator engine lacks power, consider these potential issues: * Reduce the load if it is too high. * Clean or replace the air filter if it is dirty. * Ensure the choke lever is set to the no choke position if it's partially closed. * Replace the fuel filter if it is dirty. * Inspect and clean the spark arrestor if it is dirty.
  • K
    Kimberly BrownAug 27, 2025
    How to fix DeWalt DXGNR 5700 engine runs well at no-load, but bogs when load is applied?
    • E
      Emma BrennanAug 27, 2025
      If your DeWalt Portable Generator engine runs well without a load but bogs down when a load is applied, try these solutions: * Disconnect any shorted electrical loads. * Replace the fuel filter if it's dirty. * Inspect and clean the spark arrestor if it's dirty.
  • C
    Crystal ChangAug 30, 2025
    What to do if DeWalt DXGNR 5700 engine surges or stumbles?
    • C
      Christopher ScottAug 30, 2025
      If your DeWalt Portable Generator engine surges or stumbles, try setting the choke to the halfway position until the engine runs smoothly and replace the fuel filter if it is dirty.
  • A
    Amber MoralesSep 1, 2025
    Why won't my DeWalt Portable Generator start or runs rough?
    • D
      Dawn OrtizSep 2, 2025
      If your DeWalt Portable Generator won't start or runs rough, several factors could be the cause. First, ensure the fuel shut-off is turned ON and that there's enough fresh fuel in the tank. A dirty air filter can also be the culprit, so clean or replace it. Check that the spark plug wire is connected to the spark plug, and replace the spark plug if it's bad. Additionally, make sure there's no water in the fuel, and avoid overchoking by setting the choke to the no choke position. Finally, verify that the oil level is correct.
  • E
    Emily CookSep 4, 2025
    What to do if my DeWalt Portable Generator engine is running, but there's no AC output?
    • Q
      qpattersonSep 4, 2025
      If your DeWalt Portable Generator's engine is running but there's no AC output, start by resetting the circuit breaker. Check for poor connections or defects in the cord set and repair if needed. Ensure the connected device is working correctly by testing with another device. Also, verify that the GFCI receptacle is not open by correcting any ground faults and pressing the reset button.
  • A
    amanda46Sep 6, 2025
    Why does my DeWalt DXGNR 5700 Portable Generator engine shut down during operation?
    • K
      Kevin EricksonSep 6, 2025
      If your DeWalt Portable Generator engine shuts down during operation, check if the fuel tank is empty and fill it if necessary. Also, verify that the oil level is not low and fill the crankcase to the correct level.
  • D
    David ThomasSep 9, 2025
    How to troubleshoot a DeWalt DXGNR 5700 Portable Generator that lacks power?
    • T
      Terry JohnsonSep 9, 2025
      If your DeWalt Portable Generator lacks power, first, reduce the load if it is too high. Next, check the air filter and clean or replace it if it's dirty. Finally, make sure the choke lever is set to the no choke position.

DeWalt DXGNR 5700 Specifications

General IconGeneral
Starting SystemRecoil
Fuel TypeGasoline
Rated Wattage5700 Watts
Running Watts5700 Watts
Engine Displacement389 cc
Wheel Kit IncludedYes
Electric StartNo
Battery IncludedNo
Engine TypeOHV
Peak Wattage7125 W
Starting Watts7125 W
Outlet Types120V AC