5
English
plug must be plugged into an appropriate outlet that is properly 
installed and grounded in accordance with all local codes and 
ordinances.
WARNING:  Improper connection of the equipment-grounding 
conductor can result in a risk of electrocution. Check with a qualified 
electrician or service person if you are in doubt as to whether the 
outlet is properly grounded. Do not modify the plug provided with the 
product if it will not fit the outlet installed by a qualified electrician. Do 
not use any type of adaptor with this product.
GROUND-FAULT CIRCUIT INTERRUPTER PROTECTION
This pressure washer is provided with a Ground-Fault Circuit-
Interrupter (GFCI) built into the plug of the power supply cord. This 
device provides additional protection from the risk of electric shock. 
Should replacement of the plug or cord become necessary, use only 
identical replacement parts that include GFCI protection.
Power Supply And Electrical Info
GROUND-FAULT CIRCUIT INTERRUPTER PROTECTION 
The pressure washer is factory-equipped with an electrical cord and 
a Ground Fault Circuit Interrupter (GFCI) power plug. This cord should 
only be connected to an electrical outlet installed in accordance with 
local safety regulations. 
NOTE: The power supply must be 120 V, 60 Hz and a minimum 
15amp dedicated circuit. 
  A. Inspect cord before using. Do not use if cord is damaged.
  B. Keep all connections dry and off the ground.
 C. Do not touch plug with wet hands.
 D. The pressure washer is provided with a ground fault circuit 
interrupter built into the power plug. 
If replacement of the plug or cord is needed, use only identical 
replacement parts. Contact customer service for proper replacement 
parts.
WARNING:  Test GFCI before each use. DO NOT use pressure 
washer if test below fails.
GFCI Test Procedures:
1. Plug GFCI into power receptacle.
N
M
Indicator light should illuminate.
2. Press test button (M). Light should turn
off.
3. Press reset button (N) for use. Indicator
light should illuminate.
Do not use if above test fails.
NOTE: The GFCI must be reset each time 
the pressure washer is connected to an 
electrical outlet. Reset by simply pushing the 
reset button on the GFCI power plug.
EXTENSION CORDS 
Use only extension cords that are intended for outdoor use. These 
extension cords are identified by a marking “Acceptable for use with 
outdoor appliances: store indoors while not in use”. Use only extension 
cords having an electrical rating not less than the rating of the product. 
Do not use damaged extension cords. Examine extension cord before 
using and replace if damaged. Do not abuse extension cord and do 
not yank on any cord to disconnect. 
Keep cord away from heat and sharp edges. Always disconnect the 
extension cord from the receptacle before disconnecting the product 
from the extension cord. 
When using an extension cord, observe the specification below:  
Cable Length Wire Gauge
Up to 25 ft. (7.5 m) 12 AWG Outdoor