SHUT DOWN/TRANSPORTATION (Fig. A)
1. Turn on/o switch
3
to the OFF position.
2. Unplug the unit.
3. Store the power cord
2
wrapping it around the top
handle/cord wrap
1
as shown.
4. When transporting in vehicles, secure the
machine.
MAINTENANCE
The DEWALT appliance has been designed to
operate overall long period of time with a minimum
of maintenance.Continuous satisfactory operation
depends upon proper appliance care and regular
cleaning.
WARNING: To reduce the risk of injury, turn
appliance o and disconnect appliance from
power source before installing and removing
accessories, before adjusting or changing set-
ups or when making repairs. An accidental start-up
can cause injury.
WARNING: For user servicing, the machine must
be dismantled, cleaned and serviced, as far as is
reasonably practicable, without causing risk to the
maintenance sta and others. Suitable precautions
include, decontamination before dismantling,
provision for local ltered exhaust ventilation
where the machine is dismantled, cleaning of the
maintenance area and suitable personal protection.
The manufacturer, or an instructed person, shall
perform a technical inspection at least annually,
consisting of, for example, inspection of the lter for
damage, air tightness of the machine and proper
function of the control mechanism.
When carrying out service or repair operations, all
contaminated items which cannot be satisfactorily
cleaned, are to be disposed of; such items shall
be disposed of in impervious bags in accordance
with any current regulation for the disposal of such
waste.
For dust extractors it is necessary to provide for
an adequate air change rate L in the room if the
exhaust air is returned to the room.
NOTE: Refer to national regulations is necessary.
FILTER (Fig. A, H, I)
FILTER CARE
The lters included with this vacuum are long life
lters. To be eective in minimizing dust recirculation,
the lters MUST be installed correctly and in good
condition.
WARNING: Appropriate personal protective
equipment like dust mask and gloves should be used
while handling the lters.
TO REMOVE FILTERS
1. Turn on/o switch
3
to the OFF position ( O ) and
unplug cord from outlet.
2. Release lid latches
5
és vegye le a and remove
vacuum head
4
from canister. Place vacuum
head on a level surface upside down.
3. Turn each lter
9
counterclockwise by gripping it
on the plastic end cover as shown, and carefully
remove from head, ensuring debris does not fall
into mounting hole.
NOTE: Use care to not damage lter material.
4. If the bottom side of the vacuum head needs to
be cleaned, use a cloth dampened with water and
mild soap and allow it to dry. Dispose the cloth in
an appropriate container.
5. Inspect lters for wear, tears or other damage.
NOTE: If there is any doubt on the condition of the
lters they MUST be replaced. DO NOT continue
use if lters are damaged.
WARNING: Never use compressed air or a
brush to clean lters, otherwise damage to the lter
membrane will occur which will allow dust to pass
through the lter.
If needed, gently tap against a hard surface or rinse
with room temperature water and let air dry. Cleaning
of the lters is typically unnecessary, even if the lter is
covered with dust. The automatic lter cleaning system
will maintain maximum performance and continue
to function. If visual damage to the lter membrane
exists, replace lters. Filters typically last between six
and twelve months depending on use and care.
TO INSTALL FILTERS
1. Ensure lter seal
15
is in place and is secure.
2. Line up lter threads
16
to vacuum head threads
and using moderate force, turn lter clockwise until
tight.
NOTE: Use careful to not damage lter material.
3. Place the vacuum head
4
onto the dust tank and
secure it by closing the lid latches
5
.
TO EMPTY DUST TANK (Fig. J)
WARNING: To reduce the risk of injury from
accidental starting, unplug power cord before
emptying the dust tank.
1. Remove the power head assembly of the wet/
dry vac bypulling outward on the lid clips located
on each side of the vac. Lift o the power head
assembly.
2. Dump the tank contents into the proper waste
disposal container.
BLOWING OPERATION
WARNING: To avoid injury to bystanders, keep
them clear of blowing debris.
CAUTION! Wear a dust mask if blowing creates
dust which might be inhaled.
CAUTION! To reduce the risk of hearing loss,
wear ear protectors when using the vac/blower for
extended hours or when using it in a noisy area.
CONNECTING POWER TOOL (Fig. K, L)
1. Make sure on/o switch
3
is in the ‘O’position
and the power supply is not connected.
2. There are 2 options for the next step. then connect
the power supply and turn on/o switch
3
to the ON
position ( I ), at this time the vacuum cleaner will start
working. Then connect the power supply and turn on/
o switch
3
to the ON position ( I I ), at this time the
power tool can start to use.
EN

Other manuals for DeWalt DXV30SAPTA

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the DeWalt DXV30SAPTA and is the answer not in the manual?

DeWalt DXV30SAPTA Specifications

General IconGeneral
BrandDeWalt
ModelDXV30SAPTA
CategoryVacuum Cleaner
LanguageEnglish