Questions and Answers

  • E
    erandallAug 10, 2025
    What to do if nothing lights up on my Dexcowin DX3000?
    • M
      Matthew KnightAug 10, 2025
      If nothing lights up on your Dexcowin Industrial Electrical, the cause might be a low battery. In this case, you should charge the battery.
  • S
    scott85Aug 17, 2025
    What to do if X-ray emission works, but exposure is too dark on my Dexcowin Industrial Electrical?
    • E
      Elizabeth WilliamsAug 17, 2025
      If the X-ray emission works, but the exposure is too dark, there are several possible causes: * The receptor might be defective. Try changing the receptor or comparing it with another one. * The exposure time might be too long. Try decreasing the exposure time. * The device might be defective. In this case, call a qualified service technician.
  • T
    Thomas CarterAug 25, 2025
    What to do if X-ray emission works, but exposure is too light or completely white on my Dexcowin DX3000 Industrial Electrical?
    • S
      Shelby FletcherAug 25, 2025
      If the X-ray emission works, but the exposure is too light or completely white, the following could be the reasons: 1. The receptor might be defective. Try changing the receptor or compare it with another one. 2. The exposure may be positioned incorrectly. Adjust the position of the exposure according to the user manual. 3. The exposure time might be too short. Increase the exposure time. 4. The device might be defective. In this case, call a qualified service technician.
  • W
    westalyssaSep 1, 2025
    Why is there no X-ray emission from my Dexcowin Industrial Electrical?
    • C
      Carmen SmithSep 1, 2025
      If there is no X-ray emission, here are a few possible reasons: * The generator might be preparing an exposure. Wait for it to be ready, which usually takes about 5 seconds. * The device could be in “Remote” mode. Connect with a wired remote control, or change the “Exp Key Mode” to 'Right’ and ‘Left’ on the Setting function screen. * The button might be defective. In this case, call a qualified service technician.

Summary

2 Warning and instructions

2.2 Warning for use

Provides critical warnings and precautions for using the device safely.

3 Caution and instructions

3.2 Caution and instructions

Provides cautions and instructions for product storage and usage.

5 Product Features

5.3 Product specifications

Provides detailed technical specifications for the main body and battery packs.

6 Product composition

6.3 Product Explanation

Explains individual parts of the main body, screen, buttons, and accessories.

7 How to use

7.1 Power On;Off

Step-by-step instructions for turning the device on and off.

7.2 X-RAY exposure positioning

Guidance on patient and sensor positioning for optimal X-ray imaging.

7.3 X-RAY exposure

Details the sequence for performing X-ray exposure and related settings.

8 Maintenance and storage method

8.1 Maintenance and storage

General practices for keeping the device in good condition and safe storage.

9 Inspection items before repair request

9.1 Check items before requesting inspection

Lists common symptoms and troubleshooting steps before contacting service.

9.2 Troubleshooting

10 Product specification and product warranty

11 iRay D3(DX3000)Technical document

11.3 Radiation Protection

Essential safety guidelines for protecting operators and patients from radiation.

11.6 Leakage Radiation

Presents measurements of leakage radiation at different points and distances.

11.7 Stray Radiation

Outlines test methods and results for stray radiation with and without a shield.

Dexcowin DX3000 Specifications

General IconGeneral
BrandDexcowin
ModelDX3000
CategoryIndustrial Electrical
LanguageEnglish