Light Action Condition Corrective Action
No light Low voltage – under
3 volts
Check that power
source is 12-15
volts. Verify good
power and ground
connections
4 RED flashes Brake short
(right side)
Correct the short in
right side brake wiring
3 RED flashes Brake short
left side)
Correct the short in
left side brake wiring
2 RED flashes Sensor malfunction
– no sway control
Service center repair
required
1 RED flash System malfunction Service center repair
required
Fast RED flashing Low voltage –
between 3 to 6 volts
Check the power and
ground connections
GREEN
GREEN,
RED
Flashing
RED
DSC
Status
Light
Module
Status
Light
Cable