Deye SUN-10K-SG01HP3-EU-AM2 - User Manual

Deye SUN-10K-SG01HP3-EU-AM2
63 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
R

ł
󾙓󾙒󾙒󾙓󾙕󾙔
󾙚󾙒󾙓󾙕󾙔
󾙘󾙒󾙓󾙕󾙔
󾙗󾙒󾙓󾙕󾙔
󾙓󾙔󾙒󾙓󾙕󾙔
󾙓󾙗󾙒󾙓󾙕󾙔
󾙔󾙒󾙒󾙓󾙕󾙔
󾙔󾙗󾙒󾙓󾙕󾙔

Other manuals for Deye SUN-10K-SG01HP3-EU-AM2

Questions and Answers

  • B
    blankenshipmikeSep 12, 2025
    What does Tz_AC_OverCurr_Fault mean on my Deye SUN-10K-SG01HP3-EU-AM2?
    • M
      Maria JonesSep 12, 2025
      If your Deye Inverter displays a Tz_AC_OverCurr_Fault due to an AC side over current fault, check whether the backup load power and common load power are within the specified range. Then, restart the inverter to see if the issue is resolved.
  • G
    gary10Aug 25, 2025
    What to do if my Deye SUN-10K-SG01HP3-EU-AM2 Inverter shows AC_Overload_Fault?
    • W
      woodsjaniceAug 25, 2025
      If your Deye Inverter displays an AC_Overload_Fault, check the backup load connection to ensure it is within the allowed power range.
  • P
    pbowenAug 25, 2025
    What does it mean if my Deye SUN-10K-SG01HP3-EU-AM2 shows DC_Insulation_Fault?
    • J
      jennifergibsonAug 26, 2025
      If your Deye Inverter shows a DC_Insulation_Fault, it means the PV isolation resistance is too low. You should check if the connection of PV panels and the inverter is firm and correct. Also, verify whether the PE cable of the inverter is connected to ground.
  • T
    tracyjohnsonSep 23, 2025
    What does Tz_EmergStop_Fault mean on my Deye SUN-10K-SG01HP3-EU-AM2 Inverter?
    • M
      Mark GrahamSep 23, 2025
      If your Deye Inverter displays a Tz_EmergStop_Fault, it means the inverter is being remotely controlled.
  • E
    edward17Sep 12, 2025
    What does AC_OverCurr_SW_Failure mean on my Deye Inverter?
    • J
      Jose GibsonSep 12, 2025
      If your Deye Inverter displays an AC_OverCurr_SW_Failure due to an AC side over current fault, check whether the backup load power and common load power are within the specified range. Then, restart the inverter to see if the issue is resolved.
  • J
    Jacqueline WelchSep 16, 2025
    What does INVERTER_Manual_OFF mean on my Deye SUN-10K-SG01HP3-EU-AM2?
    • S
      Sara MedinaSep 16, 2025
      If your Deye Inverter displays INVERTER_Manual_OFF, check whether the switch of the inverter is turned on. You can also try restarting the inverter and restoring the factory settings.
  • E
    Emily ThomasSep 5, 2025
    What to do if Deye SUN-10K-SG01HP3-EU-AM2 shows Grid_phase_warn?
    • J
      Johnny MaxwellSep 5, 2025
      If your Deye Inverter displays a Grid_phase_warn, check the phase sequence connection of the power grid. Try changing the grid type. If there is still no solution check the wiring at the grid end.
  • N
    Natalie MartinezSep 5, 2025
    What to do if Deye Inverter shows VW_activate?
    • D
      donnafordSep 5, 2025
      If your Deye Inverter displays VW_activate, measure whether the grid port voltage is too high and check whether the AC cable is too thin to carry current.
  • M
    matthewbuckSep 17, 2025
    What does Parallel_Version_Fault mean on my Deye SUN-10K-SG01HP3-EU-AM2?
    • M
      Mr. Nicholas DanielsSep 17, 2025
      If your Deye Inverter displays a Parallel_Version_Fault, check whether the inverter versions are consistent. You may need to contact support to upgrade the software version.
  • L
    Laura HolmesAug 30, 2025
    What does it mean if my Deye SUN-10K-SG01HP3-EU-AM2 shows DC_VoltHigh_Fault?
    • M
      michelebradleyAug 30, 2025
      If your Deye Inverter displays a DC_VoltHigh_Fault, it means the BUS voltage is too high. Check if the battery voltage is too high and verify that the PV input voltage is within the allowed range.

Deye SUN-10K-SG01HP3-EU-AM2 Specifications

General IconGeneral
ModelSUN-10K-SG01HP3-EU-AM2
TypeHybrid Inverter
Rated Power10kW
Max. Output Power11kW
Max. DC Input Power13kW
Max. PV Input Voltage1000V
Number of MPPTs2
AC Output Frequency50/60Hz
THDi<3%
Peak Efficiency98.4%
DC Connection TypeMC4
AC Connection TypeScrew terminal
Protection DegreeIP65
CoolingSmart cooling
MPPT Voltage Range200 V - 1, 000 V
AC Voltage Range180-280Vac
Power Factor0.8 leading to 0.8 lagging
Efficiency98%
Operating Temperature Range-25°C to +60°C
CommunicationRS485, Wi-Fi