Model | SUN-10K-G05-LV |
---|---|
Type | Hybrid Inverter |
Rated Power | 10kW |
Max. Output Power | 11kW |
Max. DC Input Power | 13kW |
Number of MPPT | 2 |
AC Voltage Range | 180-280V |
AC Output Frequency | 50/60 Hz |
THDI | <3% |
Max. Charging Power | 10kW |
Max. Discharging Power | 10kW |
Protection Class | IP65 |
Max DC Input Current | 26 A |
Max. Input Current per MPPT | 13 A |
Rated AC Voltage | 230 V |
Power Factor | 0.8 leading to 0.8 lagging |
Protection | AC Short Circuit Protection |
Communication | RS485 |
Battery Type | Lithium |
Describes the physical appearance of the SUN-10K-G05-LV and SUN-12K-G05-LV on-grid inverters.
Explains the meaning of various warning, safety, and information labels used throughout the manual.
Lists all components included in the inverter package for installation and setup.
Provides essential guidelines for safe lifting, transport, and handling of the inverter unit.
Details the meaning of important safety symbols like Warning, Shock Hazard, and High Temperature Hazard.
Crucial safety guidelines for electrical installation and operation to prevent hazards.
Important notes and precautions for safe and correct operation of the inverter.
Diagram of the inverter's front panel, showing display indicators and controls.
Explanation of the LED status indicators (DC, AC, NORMAL, ALARM) on the inverter.
Description of the function of the Esc, Up, Down, and Enter buttons on the inverter.
Details the information displayed on the inverter's two-line Liquid Crystal Display (LCD).
Criteria for choosing a suitable and safe location for inverter installation, considering environmental factors.
Lists recommended tools required for the proper installation of the inverter.
Step-by-step guide for securely mounting the inverter onto a wall using the provided bracket.
Parameters to consider when selecting PV modules compatible with the inverter.
Instructions for safely connecting PV modules to the inverter's DC input terminals.
Procedure for connecting the AC power source to the inverter's input terminals.
Details the method for connecting the ground wire for electrical safety and performance.
Recommendation for installing a circuit breaker for overcurrent protection, with specifications.
Guide for connecting the inverter for remote monitoring via Wi-Fi or other communication methods.
Step-by-step instructions for safely starting the inverter and initiating energy production.
Outlines the correct sequence for safely shutting down the inverter.
Explains the zero-export function and supported energy meters, including connection diagrams.
Details configuring multiple inverters with a single meter for zero-export functionality.
Step-by-step guide for enabling and using the zero-export feature through the energy meter.
Important safety hints and operational suggestions for using the zero-export function.
Guide to viewing PV load power and system data on the solarman monitoring platform.
Describes information shown on the inverter's LCD during normal operation and standby.
Overview of submenus like Device Information, Fault Record, and Parameter settings.
Configuration options for time, language, display, and factory reset settings.
Details on grid protection parameters (e.g., voltage, frequency) requiring password access.
Configuration for communication parameters like Modbus address and baud rate.
Comprehensive list of error codes displayed by the inverter and their corresponding troubleshooting steps.
Detailed technical data for PV string input, AC output, efficiency, and protection features.
Statement of compliance with relevant EU directives for electromagnetic compatibility and low voltage.