1
DGBOX
rev. 1602
Inverter electronic control panels
for single pumps or pumping units
OPERATOR’S AND MAINTENANCE MANUAL
Model V in V out A P (kW) P (HP)
DGB MV 30
3 ~ 400V 3 ~ 400V
8 3 4
DGB MV 55
3 ~ 400V 3 ~ 400V
14 5,5 7,5
DGB MV 75
3 ~ 400V 3 ~ 400V
18 7,5 10
DGB MVF 30
3 ~ 400V 3 ~ 400V
8 + 8 3 + 3 4 + 4
DGB MVF 55
3 ~ 400V 3 ~ 400V
14 + 14 5,5 + 5,5 7,5 + 7,5
DGB MVF 75
3 ~ 400V 3 ~ 400V
18 + 18 7,5 + 7,5 10 + 10
DGB MW 30
3 ~ 400V 3 ~ 400V
8 + 8 3 + 3 4 + 4
DGB SV 30
3 ~ 400V 3 ~ 400V
8 3 4
DGB SV 55
3 ~ 400V 3 ~ 400V
14 5,5 7,5
DGB SV 75
3 ~ 400V 3 ~ 400V
18 7,5 10
10154507A .03 - 170530
EN

Questions and Answers

  • K
    kristen23Sep 12, 2025
    Why is my DGFLOW Control Panel pump's performance low?
    • D
      davidhoffmanSep 12, 2025
      If the DGFLOW Control Panel's pump performance is below the plate specifications, it could be due to air inside the suction manifold or a blocked/damaged pump. Bleed the suction system and inspect the pump to eliminate any blockages or damage.
  • D
    Debra SaundersSep 15, 2025
    How to fix a tripped circuit breaker on DGFLOW Control Panel?
    • C
      Christopher NguyenSep 15, 2025
      If the current circuit breaker has tripped, it may be because the residual current circuit breaker is inadequate for the inverter supply. Replace the residual current circuit breaker with a model suitable for pulsating components and direct current (class A or B).
  • M
    Mary StoutNov 22, 2025
    Why won't my DGFLOW Control Panel's VARIABLE SPEED pump start?
    • Z
      zguerraNov 22, 2025
      If the VARIABLE SPEED pump fails to start, several issues could be the cause. These include the pump being out of service, lack of water at suction, excessive overcurrent absorption, short circuit, no communication between control board and power board, no pressure signal, lack of phase during operation, wrong power wiring, no level signal, or the pump working dry. Here are a few things to check: * Put the pump back into service. * Check for water at suction, prime the pump, and clean the suction. * Check and correct the motor rotation and set the parameter PD to a lower value. * Check the correct current setting and voltage at pump terminals. * Ensure the motor is turning freely and there are no short circuits. * Check the integrity of the connection cable and connections. * ...

Summary

Safety Standards

Installation Guide

Description of Main Components

Input and Output Signal Connections

Starting Up the System

Self-Learning Configuration

Main Menu and Parameter Configuration

Base Setup Configuration

Core configuration parameters for initial setup.

Advanced Setup Configuration

Advanced parameters for optimizing system operation.

Hardware Setup Configuration

Configuration of signal inputs, outputs, and sensors.

Operation Parameter Settings

System Pressure and Rated Current Setup

Configuring system pressure and pump 1 rated current.

Checking Motor Rotation Direction

Motor Frequency and Operation Settings

Functional Test Mode

Alarm and Fault Management

Device Operating Modes

Configuration Mode

Accessing and modifying system parameters.

Base Setup Configuration Details

Advanced Setup Configuration Details

Hardware Setup Configuration Details

Maintenance Menu

Functional Test Procedures

Work Mode Operation Details

Out of Service Mode Details

Startup Procedure

Troubleshooting and Fault Resolution

DGFLOW DGB MVF 30 Specifications

General IconGeneral
BrandDGFLOW
ModelDGB MVF 30
CategoryControl Panel
LanguageEnglish