DIEL MT 200 Specifications

General IconGeneral
Supply voltage24 VDC
Power consumption5 W
Operating temperature-10°C to +55°C
Number of inputs8
Number of outputs8
Input Voltage24 VDC
Output Voltage24 VDC
Protection ClassIP20

Summary

Installation and Instructions Manual

Technical Features Overview

Details about the device's physical and electrical specifications.

Dimensions

Specifies the physical dimensions and weight of the device.

Power Supply Specifications

Details the voltage, frequency, and absorption for power supply.

Input and Output Capabilities

Describes analogical inputs and relay outputs of the device.

Key Device Characteristics

Lists features like box material, protection degrees, display, and alerts.

Further Technical Details

Covers storage, isolation, software config, resolution, working temp, humidity, connectors.

Assembly Guidance

Provides guidance on how to install the device into a panel.

Electrical Connections

Explains how to perform connections on the terminal board.

Programming the Device

Details the process of configuring device parameters via the interface.

Programming Menu Options

Details programming modes (0-4) for fan control and advanced settings.

Setting Pre-alarm and Alarm Temperatures

Guides on how to set pre-alarm and alarm temperatures.

Setting Fan Control Thresholds

Explains how to set low (L) and high (H) fan thresholds.

Display and Operating Modes

Describes automatic/manual display modes and parameter visualization.

Advanced Programming Menu

Details independent threshold programming for each channel.

Relay Testing Procedure

Explains how to perform a test on the device's relays.

Thermometrical Probe Diagnostics

Describes how probe errors (disconnect, short circuit) are indicated.

Intervention Logic

Explains how the device reacts to temperature changes and triggers relays/LEDs.

Warranty Conditions

Outlines the warranty period, conditions, and exclusions.

Critical Safety Precautions

Warns against specific electrical tests and direct transformer connections.