Operation
Cr 0 isaxedspan(nocycling),withavarianceof+/-0.3°C(+/-0.6°F).Theheatingunit
will operate at full power and the power bar will appear full. This function is for users who
do not want their electric heating devices turning on and off frequently. This is the recom-
mended setting for fan-assisted electric heating devices.
Cr 1 (Default) is a 20 second cycle rate with proportional heating. This means the heating
will be turned on and off once every 20 seconds to provide a stable room temperature. This
cycle rate allows a proportional level of power to the heating device. This is indicated on
thethermostatdisplaybythepowerbarwhichwillbepartiallylled;indicatingtheamount
of power going to the heater. This setting is recommended for non-fan assisted baseboards
andelectricheatingdevicesandwillprovidethemostenergyefcientheatingandastable
temperature.
Cr 2 is a 240 second span. This means the heating will be turned on and off once every
240 seconds. This is the recommended setting for fan assisted heaters, radiant ceilings
and convectors.
1. While it is still in the Options Setting mode, press SET again to advance to the
secondoption(CR:1willashonscreen).
2. Press or to select the cycle rate
Option 2: Selecting the Heat Cycle Rate . . . continued