EasyManua.ls Logo

Dimplex LA 9 MI - User Manual

Dimplex LA 9 MI
63 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
ContactDetails
Pleasenotethatsomeofthecontactdetailson
thisPDFdocumentmaynotbecurrent.
Pleaseusethefollowingdetailsifyouneedto
contactus:
Telephone:08448793588
Email:customer.services@gdcgroup.co.uk
Thecustomersupportsectionofourwebsitealsofeaturesawide
rangeofinformationwhichmaybeofusetoyouandisavailable
24hoursaday.Itincludes:
Operatingandinstallationinstructions
Easy‘Howtouse’guidesforstorageheaters
Serviceandrepairs
Where
tobuyourproducts
Literaturedownloads
Heatingrequirementcalculator
Visit‐www.dimplex.co.uk/support
A division of GDC Group Ltd
Millbrook House Grange Drive Hedge End Southampton SO30 2DF
www.dimplex.co.uk
Re
g
istered No: 1313016 En
g
land
VAT GB 287 1315 50004
EEE Producer Registration Number
WEE/GE0057TS
Paper from sustainable sources

Table of Contents

Other manuals for Dimplex LA 9 MI

Questions and Answers

Summary

Contact Details

Supporting Documents

Technical Manuals

Contains information required during the planning stages.

Installation Instructions

Contains the necessary information required during the installation.

User Guides

Contains information for the user for operation and maintenance of the system.

Introduction to Heat Pumps

Benefits of a Heat Pump

Explains advantages of heat pumps over traditional heating systems.

How a Heat Pump Works

Explains the refrigeration cycle and heat transfer process.

Intended Use

Specifies the device's intended application as per manufacturer.

Air as a Heat Source

Discusses factors for choosing air source vs. ground source heat pumps.

Advantages of Inverter Compressors

Details benefits of variable speed compressor technology.

Advantages of Fixed Speed Compressors

Explains the design and efficiency of fixed speed compressors.

Heat Pump Labelling

Explains the coding convention for product identification.

Comparison of LA MS and LA MI Ranges

Compares features and capabilities of different heat pump ranges.

Selection and Sizing of the Heat Pump

Process to Select a Heat Pump

Outlines the steps for choosing the correct heat pump model.

Mono Energy Operation

Describes how the heat pump operates in single energy mode.

Determining Building Heat Loss

Explains the importance and methods for calculating heat loss.

Dimplex Design Service

Details Dimplex's free service for heat loss calculation and product specification.

Estimating Building Heat Loss

Provides methods and rules of thumb for estimating heat loss.

Drying-out of Buildings

Advises on heat pump use during building drying and humidity management.

Sizing Example 1

Illustrates heat pump sizing with a practical example.

Sizing Example 2

Demonstrates heat pump sizing with a second practical example.

System Controls in a Domestic Setting

Boiler Interlock

Explains interlock requirements for preventing energy wastage.

Horstmann PRT Thermostat

Details the features and use of the Horstmann thermostat for heat pumps.

Heat Pump Controller

Describes the controller for safe and efficient heat pump operation.

Weather Compensation

Explains how weather compensation optimizes efficiency by adjusting flow temperature.

Selection of Heat Emitters and Flow Temperatures

Minimising Flow Temperature

Explains the benefits of lowering flow temperature for system performance.

Considerations for Fan Convectors

Discusses principles for connecting fan convectors to heat pumps.

DHW Preparation with Inverter Heat Pumps

Dimplex EC-Eau Cylinder Range

Introduces the range of stainless steel cylinders for hot water.

Dimplex ECS Combination DHW and Buffer Cylinders

Describes combination cylinders offering DHW and buffer functions.

Heat Pump Power for Hot Water Preparation

Addresses the heat pump's role in hot water production and sizing.

Selecting a DHW Cylinder

Guides on choosing a suitable DHW cylinder for heat pump systems.

Sterilisation

Provides guidance on domestic hot water sterilisation for legionella prevention.

Secondary Circulation Pipes

Explains the use and considerations for secondary circulation pipes.

Installation Considerations

Physical Location

Advises on selecting an appropriate outdoor location for the heat pump.

Fixing of the Heat Pump

Details methods for securely fixing the heat pump to its base.

Wall Mounting

Provides guidance on wall mounting the heat pump, including condensate management.

Ventilation

Explains the importance of adequate ventilation for heat pump operation.

Minimum Maintenance Clearances

Specifies required clearances for performing maintenance tasks.

Sound Insulation Measures

Discusses measures to minimize noise impact on surroundings.

Air Quality

Details air quality factors that can affect heat pump lifespan and warranty.

Local Planning Regulation

Advises installers to verify local planning regulations before installation.

MCS Planning Standard

Outlines the MCS standard for noise assessment and planning permission.

Town and Country Planning, England

Summarizes planning permission requirements for heat pumps in England.

Planning in Wales and Northern Ireland

States planning permission requirements for installations in Wales and Northern Ireland.

Town and Country Planning, Scotland

Outlines permitted development rules for heat pumps in Scotland.

Heating System Connection

External Pipe Work

Advises on proper insulation and material choice for external pipe work.

Minimum Water Volume

Specifies the minimum system water volume requirement for operation.

Buffer Tank

Explains the role of a buffer tank in defrosting and runtime extension.

Minimum Heating Water Flow Rate

Details the importance of maintaining the correct heating water flow rate.

Taconova Flow Checker

Describes the use of the Taconova flow checker for verifying flow rate.

Plumbing Connections

Lists fitting sizes and torque values for plumbing connections.

Frost Protection

Explains measures to prevent freezing during cold weather or power failures.

Condensate

Details condensate formation and drainage requirements.

Flushing the System

Guides on flushing the system before connecting the heat pump to remove impurities.

Filter

Highlights the importance of installing a filter to protect the heat pump.

Filling the System

Outlines the process and requirements for filling the system with water.

De-aeration

Explains how to remove air from the system to ensure proper water flow.

Adjusting the Water Flow Rate

Details how to adjust pump speed for optimal flow and temperature difference.

Expansion Vessel Sizing

Discusses the need for expansion vessels and sizing considerations.

2 Port Valves

Describes the function and installation of 2-port valves for mode switching.

Controlling DHW Temperature

Explains how the DHW temperature is controlled and set.

Electrical Connection

Routing of Cables within the Heat Pump

Guides on safely routing electrical cables inside the heat pump unit.

Ducting Cables

Advises on protecting external cables with ducting against elements and damage.

Connection of the Power Supply to the Heat Pump

Details the process of connecting the heat pump to the main power supply.

Main Power Supply Cable

Covers cable selection, rating, and isolation requirements for power connection.

Inline Flow Boiler

Explains the role and function of the inline flow boiler for supplementary heating.

Domestic Hot Water Immersion

Describes how the heat pump controls the DHW immersion heater.

Controller Cable

Details the connection and limitations of the controller cable.

Connection with the System

Provides general information on communication connections for system integration.

Installation of the Controller

Gives guidance on the optimal placement and installation of the heat pump controller.

System Health Checks

Heat Pump Checks

Lists checks for the heat pump unit itself, including the fan and sound.

Electrical Checks

Covers checks for electrical connections, earth wire, and supply voltage.

Hydraulic Checks

Details checks for water pressure and pressure relief valve operation.

Cylinder Checks

Specifies checks for cylinder temperature, immersion cut-outs, and relief valve.

Wall Mounted Thermostat Checks

Advises on thermostat battery replacement and checking heating periods.

Heat Pump Controller Checks

Suggests checking controller panel operation and user settings for efficiency.

Standard Packages

Package 1 and 2

Describes configurations for heating and DHW with combined or separate cylinders.

Package 3

Details configuration for heating only, requiring a buffer tank.

Technical Specification of the LA MI Range

Performance Data Overview

Presents performance metrics including output, COP, sound levels, and flow rates.

LA 6 MI Performance Data

Shows heating capacity, power consumption, and COP curves for the LA 6 MI model.

LA 9 MI Performance Data

Displays performance charts for heating capacity, power, and COP for the LA 9 MI model.

LA 12 MI Performance Data

Presents performance curves for heating capacity, power consumption, and COP for the LA 12 MI model.

LA 16 MI Performance Data

Shows performance data charts for heating capacity, power, and COP for the LA 16 MI model.

Product Dimensions (LA 6;9 MI)

Provides dimensional drawings for the LA 6 MI and LA 9 MI heat pump models.

Product Dimensions (LA 12;16 MI)

Displays dimensional drawings for the LA 12 MI and LA 16 MI heat pump models.

Spare Parts (LA 6;9 MI)

Shows exploded views of spare parts for LA 6 MI and LA 9 MI models.

Spare Parts (LA 12;16 MI)

Displays exploded views of spare parts for LA 12 MI and LA 16 MI models.

Information for DHW Cylinder with Buffer - ECS125 HP-580

Information for DHW Cylinder with Buffer - ECS150 HP;75-580

Information for DHW Cylinder with Buffer - ECS210 HP;75-580

Summary

Contact Details

Supporting Documents

Technical Manuals

Contains information required during the planning stages.

Installation Instructions

Contains the necessary information required during the installation.

User Guides

Contains information for the user for operation and maintenance of the system.

Introduction to Heat Pumps

Benefits of a Heat Pump

Explains advantages of heat pumps over traditional heating systems.

How a Heat Pump Works

Explains the refrigeration cycle and heat transfer process.

Intended Use

Specifies the device's intended application as per manufacturer.

Air as a Heat Source

Discusses factors for choosing air source vs. ground source heat pumps.

Advantages of Inverter Compressors

Details benefits of variable speed compressor technology.

Advantages of Fixed Speed Compressors

Explains the design and efficiency of fixed speed compressors.

Heat Pump Labelling

Explains the coding convention for product identification.

Comparison of LA MS and LA MI Ranges

Compares features and capabilities of different heat pump ranges.

Selection and Sizing of the Heat Pump

Process to Select a Heat Pump

Outlines the steps for choosing the correct heat pump model.

Mono Energy Operation

Describes how the heat pump operates in single energy mode.

Determining Building Heat Loss

Explains the importance and methods for calculating heat loss.

Dimplex Design Service

Details Dimplex's free service for heat loss calculation and product specification.

Estimating Building Heat Loss

Provides methods and rules of thumb for estimating heat loss.

Drying-out of Buildings

Advises on heat pump use during building drying and humidity management.

Sizing Example 1

Illustrates heat pump sizing with a practical example.

Sizing Example 2

Demonstrates heat pump sizing with a second practical example.

System Controls in a Domestic Setting

Boiler Interlock

Explains interlock requirements for preventing energy wastage.

Horstmann PRT Thermostat

Details the features and use of the Horstmann thermostat for heat pumps.

Heat Pump Controller

Describes the controller for safe and efficient heat pump operation.

Weather Compensation

Explains how weather compensation optimizes efficiency by adjusting flow temperature.

Selection of Heat Emitters and Flow Temperatures

Minimising Flow Temperature

Explains the benefits of lowering flow temperature for system performance.

Considerations for Fan Convectors

Discusses principles for connecting fan convectors to heat pumps.

DHW Preparation with Inverter Heat Pumps

Dimplex EC-Eau Cylinder Range

Introduces the range of stainless steel cylinders for hot water.

Dimplex ECS Combination DHW and Buffer Cylinders

Describes combination cylinders offering DHW and buffer functions.

Heat Pump Power for Hot Water Preparation

Addresses the heat pump's role in hot water production and sizing.

Selecting a DHW Cylinder

Guides on choosing a suitable DHW cylinder for heat pump systems.

Sterilisation

Provides guidance on domestic hot water sterilisation for legionella prevention.

Secondary Circulation Pipes

Explains the use and considerations for secondary circulation pipes.

Installation Considerations

Physical Location

Advises on selecting an appropriate outdoor location for the heat pump.

Fixing of the Heat Pump

Details methods for securely fixing the heat pump to its base.

Wall Mounting

Provides guidance on wall mounting the heat pump, including condensate management.

Ventilation

Explains the importance of adequate ventilation for heat pump operation.

Minimum Maintenance Clearances

Specifies required clearances for performing maintenance tasks.

Sound Insulation Measures

Discusses measures to minimize noise impact on surroundings.

Air Quality

Details air quality factors that can affect heat pump lifespan and warranty.

Local Planning Regulation

Advises installers to verify local planning regulations before installation.

MCS Planning Standard

Outlines the MCS standard for noise assessment and planning permission.

Town and Country Planning, England

Summarizes planning permission requirements for heat pumps in England.

Planning in Wales and Northern Ireland

States planning permission requirements for installations in Wales and Northern Ireland.

Town and Country Planning, Scotland

Outlines permitted development rules for heat pumps in Scotland.

Heating System Connection

External Pipe Work

Advises on proper insulation and material choice for external pipe work.

Minimum Water Volume

Specifies the minimum system water volume requirement for operation.

Buffer Tank

Explains the role of a buffer tank in defrosting and runtime extension.

Minimum Heating Water Flow Rate

Details the importance of maintaining the correct heating water flow rate.

Taconova Flow Checker

Describes the use of the Taconova flow checker for verifying flow rate.

Plumbing Connections

Lists fitting sizes and torque values for plumbing connections.

Frost Protection

Explains measures to prevent freezing during cold weather or power failures.

Condensate

Details condensate formation and drainage requirements.

Flushing the System

Guides on flushing the system before connecting the heat pump to remove impurities.

Filter

Highlights the importance of installing a filter to protect the heat pump.

Filling the System

Outlines the process and requirements for filling the system with water.

De-aeration

Explains how to remove air from the system to ensure proper water flow.

Adjusting the Water Flow Rate

Details how to adjust pump speed for optimal flow and temperature difference.

Expansion Vessel Sizing

Discusses the need for expansion vessels and sizing considerations.

2 Port Valves

Describes the function and installation of 2-port valves for mode switching.

Controlling DHW Temperature

Explains how the DHW temperature is controlled and set.

Electrical Connection

Routing of Cables within the Heat Pump

Guides on safely routing electrical cables inside the heat pump unit.

Ducting Cables

Advises on protecting external cables with ducting against elements and damage.

Connection of the Power Supply to the Heat Pump

Details the process of connecting the heat pump to the main power supply.

Main Power Supply Cable

Covers cable selection, rating, and isolation requirements for power connection.

Inline Flow Boiler

Explains the role and function of the inline flow boiler for supplementary heating.

Domestic Hot Water Immersion

Describes how the heat pump controls the DHW immersion heater.

Controller Cable

Details the connection and limitations of the controller cable.

Connection with the System

Provides general information on communication connections for system integration.

Installation of the Controller

Gives guidance on the optimal placement and installation of the heat pump controller.

System Health Checks

Heat Pump Checks

Lists checks for the heat pump unit itself, including the fan and sound.

Electrical Checks

Covers checks for electrical connections, earth wire, and supply voltage.

Hydraulic Checks

Details checks for water pressure and pressure relief valve operation.

Cylinder Checks

Specifies checks for cylinder temperature, immersion cut-outs, and relief valve.

Wall Mounted Thermostat Checks

Advises on thermostat battery replacement and checking heating periods.

Heat Pump Controller Checks

Suggests checking controller panel operation and user settings for efficiency.

Standard Packages

Package 1 and 2

Describes configurations for heating and DHW with combined or separate cylinders.

Package 3

Details configuration for heating only, requiring a buffer tank.

Technical Specification of the LA MI Range

Performance Data Overview

Presents performance metrics including output, COP, sound levels, and flow rates.

LA 6 MI Performance Data

Shows heating capacity, power consumption, and COP curves for the LA 6 MI model.

LA 9 MI Performance Data

Displays performance charts for heating capacity, power, and COP for the LA 9 MI model.

LA 12 MI Performance Data

Presents performance curves for heating capacity, power consumption, and COP for the LA 12 MI model.

LA 16 MI Performance Data

Shows performance data charts for heating capacity, power, and COP for the LA 16 MI model.

Product Dimensions (LA 6;9 MI)

Provides dimensional drawings for the LA 6 MI and LA 9 MI heat pump models.

Product Dimensions (LA 12;16 MI)

Displays dimensional drawings for the LA 12 MI and LA 16 MI heat pump models.

Spare Parts (LA 6;9 MI)

Shows exploded views of spare parts for LA 6 MI and LA 9 MI models.

Spare Parts (LA 12;16 MI)

Displays exploded views of spare parts for LA 12 MI and LA 16 MI models.

Information for DHW Cylinder with Buffer - ECS125 HP-580

Information for DHW Cylinder with Buffer - ECS150 HP;75-580

Information for DHW Cylinder with Buffer - ECS210 HP;75-580

Dimplex LA 9 MI Specifications

General IconGeneral
BrandDimplex
ModelLA 9 MI
CategoryHeat Pump
LanguageEnglish

Related product manuals