www.dimplex.de/en 1810/C EN-12
PLX 050E - PLX 300E English
10.8 Increasing the set point
The room heating device is delivered from the factory
with an adjustable temperature range of 7°C to 26° C.
The upper limit value can be increased (max. 32° C) or
lowered as required.
Press and hold the MENU key, the BACK key and
the ENTER key for five seconds.
SP display flashes.
Press the ENTER key. °C display flashes.
Press the ENTER key. Display 26 (limit value set at
the factory) flashes.
Press or to increase or lower the desired limit
value.
Press the ENTER key.
Confirm the BACK key to return to the standard
display.
10.9 Service information
This information is exclusively for service technicians.
The following information can be displayed:
UI number Service number display
CC number: Service number electronics
ID number: Service number heating device
Press and hold the ENTER key for five seconds.
INFO display flashes.
Press or to select the display Ui, CC or id.
Confirm the BACK key twice to return to the stand-
ard display.
Display id is a code with 12 digits.
The first 4 digits are shown on level 1.
Press or to select the next level (2,3).
11. Warranty
This product is supplied with a two-year warranty
according to our terms of guarantee.
12. Note on disposal
Do not dispose of the unit with general
household waste. The device must be taken to
a local waste disposal plant.
13. Technical data
Glen Dimplex Deutschland GmbH Tel.: +49 9221 709 545
Am Goldenen Feld 18 Fax.: +49 9221 709 924545
D - 95326 Kulmbach E-mail: service@gdts.one
Unit type PLX 050E,
PLX 075E
PLX 100E,
PLX 150E
PLX 200E,
PLX
250E/300E
Nominal voltage 1/N/PE, 230 - 240 V~
Degree of protection IP24, splash-proof
Dimensions (W x H x D) 450 x 430
x 108 mm,
620 x 430
x 108 mm
620 x 430
x 108 mm,
690 x 430
x 108 mm
860 x 430
x 108 mm,
860 x 430
x 143 mm
Weight 4.8 kg,
6.2 kg
6.2 kg,
6.6 kg
8.0 kg,
8.6 kg
Heat output
Nominal heat
output
P
nom
0.5 kW,
0.75 kW
1.0 kW,
1.5 kW
2.0 kW,
3.0 kW
Minimum heat
output (guide
value)
P
min
0.5 kW,
0.75 kW
1.0 kW,
1.5 kW
2.0 kW,
3.0 kW
Maximum
continuous heat
output
P
max, C
0.5 kW,
0.75 kW
1.0 kW,
1.5 kW
2.0 kW,
3.0 kW
Intrinsic consumption
With nominal heat
output
el
max
0.0 W 0.0 W 0.0 W
With minimum
heat output
el
min
0.0 W 0.0 W 0.0 W
In standby state el
SB
0.5 W 0.5 W 0.5 W
Regulator for heat output
Electronic room temperature controller with week program, window
monitoring, adaptive control of the heating start and operating time
limit