OPERATOR’S MANUAL with Maintenance Information
Maintenance
48
B-11
Test the Drive Speed -Raised Position
Dingli requires that this procedure be
performed every 250 hours or quarterly,
whichever comes first.
Proper drive function movement is essential to
safe machine operation. The drive function
should respond quickly and smoothly to
operator control. Drive performance should
also be free of hesitation, jerking and unusual
noise over the entire proportionally control led
speed range.
1 Create start and finish lines by marking
two lines on the ground 12.2m apart.
2 Turn the key switch to platform controls
3 Pull out the platform and ground red
Emergency Stop button to the on position.
4 Press and hold the function enable button.
Raise the platform approximately 4.0m
from the ground.
5 Choose a point on the machine; i.e.,
contact patch of a tire, as a visual
reference for use when crossing the start
and finish lines.
6 Bring the machine to maximum drive
speed before reaching the start line. Begin
timing when your reference point on the
machine crosses the start line.
7 Continue at full speed and note the time
when the machine reference point passes
over the finish line. The time is less than
40 sec.