TROUBLESHOOTING
Troubleshooting
세척 유지 방법
Troubleshooting
Symptoms Measure Methods
Display is Blank
Check that the unit is plugged in and/or the breaker is
on.
Check that voltage is present at the unit.
Contact the Factory.
Power on, but pan
not heating.
Check that a pot is proper for Induction Range or that a
pot is placed in center of the top plate.
Contact the Factory.
Unit stops heating
Or output is
weakened.
Check the surrounding temperature.
Check the product's ventilation.
Check that the temperature of the ceramic top plate is above 500F.
Check that the pan is properly placed.
Check the set timer value.
Check if the 12 hour maximum run time has been exceeded.
Etc…
(display
ed)
U, 00
Make sure you have a valid pan.
Check that the pan has a flat bottom.
E4, E6
Turn off and unplug the unit. Allow the unit to cool off.
Plug back in and try again.
E5
Check that the temperature sensor is connected to the product correctly.
"E5" error means that the sensor isn't connected to the product.
E2,E3,E7
Unplug or turn of the breaker for at least 1 minute, plug
back in and try again
E1,E8,E9
Contact the Factory.