Service - 100 410sx Operators Manual
500 Hour
500 Hour
Tractor
Change Hydraulic Fluid and Filters
Change hydraulic fluid and filters every 500 hours.
To change hydraulic fluid:
1. With fluid warm, remove drain plug (1), located
at bottom of reservoir on right side of tractor.
2. Drain fluid and replace plug.
3. Fill through fill cap (2) to center of reservoir
sight glass (3) with THF. Reservoir capacity is
13.2 gal (50 L).
Location Task Notes
TRACTOR Change hydraulic fluid and filter 13.2 gal (50 L) THF
Lubricate and inspect u-joints MPG
Check ground drive differential oil level MPL
Check ground drive gearbox oil level MPL
PLOW Change plow vibrator oil 2.4 pt (1 L) MPL