SK752 Operator’s Manual Controls - 23
Gauges and Indicators
Item Description Notes
1. Glow plug button To help start cold engine, turn
ignition switch to first position.
Press glow plug button as
directed in notes.
Release button, then turn
ignition switch all the way
clockwise to start.
IMPORTANT: Press glow plug button
according to temperatures below.
If ambient temperature is below
40° F (4° C), press and hold
button for 5 seconds.
If ambient temperature is below
20° F (-7° C), press and hold
button for 10 seconds.
Do not press button for more than
20 seconds continuously.
2. Engine coolant
temperature gauge
Displays coolant temperature. IMPORTANT: If temperature goes
above 230°F (110°C):
1. Stop operation, set throttle to low
idle, and allow engine to cool.
2. Stop engine.
3. Check coolant level.
4. Ensure radiator is clean.
3. Engine oil pressure
indicator
Lights when engine oil
pressure is low.
Also lights briefly when
engine is started.
Engine will stop.
1. Check oil level.
2. Check for leaks before starting
engine.
c00ic108h.eps