SK752 Operator’s Manual Service - 63
Startup/10 Hour
Check Hydraulic Fluid Level
Check hydraulic fluid level at startup and every
10 hours. Maintain fluid level at halfway point on
sight glass (2), when engine is off, cylinders are
fully retracted, and fluid is cool. If low, add THF at
fill (1).
Check Brake Operation
Check brake operation at startup and every 10
hours or more often when conditions warrant..
Ensure parking brake pin (shown) moves
freely allowing brake to be engaged and
disengaged.
Clean mud and debris from area around pin.
Check Lug Nut Torque
Check lug nut torque at 10 hours, 50 hours and
every 200 hours thereafter. Tighten to 88-95 ft•lb
(108-129 N•m) as needed.
IMPORTANT: Engine must be running to
check brake operation.